How many tesla is a neodymium magnet?
The answer depends on where you measure. In the 10×3 mm cylinder example below, calculated field falls from about 0.334 T at the pole centre to 0.025 T at 10 mm away. The magnet and material have not changed; the measurement position has.
1 tesla = 10,000 gauss; 1 mT = 10 gauss. A reading of 250 mT is 2,500 G. A Hall probe measures flux density at its active element in a defined direction. That local reading differs from material remanence Br and from a pull-force rating.[1]
Why distance changes a gauss reading
Consider an ideal axially magnetized cylinder, 10 mm in diameter and 3 mm thick, with Br = 1.30 T. The following estimate uses uniform magnetization and a recoil relative permeability approximated as one, with no nearby steel or other magnets. It is an educational calculation, not a measurement or a promised product value.
| Distance z | Bz (T), approx. | Gauss, approx. |
|---|---|---|
| 0 mm | 0.334 T | 3,344 G |
| 1 mm | 0.279 T | 2,786 G |
| 3 mm | 0.165 T | 1,649 G |
| 5 mm | 0.092 T | 916 G |
| 10 mm | 0.025 T | 253 G |
The estimate is Bz = (Br/2) × [(z + t)/√(R² + (z + t)²) − z/√(R² + z²)], where R = 5 mm and t = 3 mm. Use one length unit consistently. The reduction comes from geometry and distance, not a change in grade. The calculation is for the centreline, so it cannot predict the field at a corner or the transverse component.
A probe housing touching the magnet does not put its active sensor at z = 0. Its internal setback adds separation. Probe size also matters: in a steep gradient, a finite sensing area averages a region instead of sampling an infinitesimal point. K&J's measurement example and Arnold's measurement guide explain both problems.[3] [4]
A repeatable Hall-probe measurement
- Choose the quantity and range. Specify Bz, another component, or a three-axis vector magnitude. Confirm the probe orientation, measurement range and calibration.
- Locate the active element. Use the probe manufacturer's mechanical drawing. Reference the sensing area to a magnet datum, not just the outer probe tip.
- Fix the geometry. Use a nonmagnetic fixture with a stop for distance and lateral position. Keep other magnets, steel tools and supports out of the measurement region.
- Control zero and temperature. Follow the instrument's zeroing procedure and record the measurement temperature. Do not assume an arbitrary point on the bench is field-free.
- Check repeatability. Remove and reseat the part several times. Record the spread before setting an acceptance window tighter than the fixture can reproduce.
A one-axis probe rotated by an angle θ from a locally uniform field measures approximately B cos θ. That relationship does not correct an unknown three-dimensional field or a position error. Probe documentation identifies the sensitive axis and active area; use those details in the fixture drawing.[5]
For a ring with a multipole pattern, one centre reading can miss a reversed or weak pole. Define angular positions, radius, height and rotation direction for a field scan. For a Hall-switch application, check field along the full motion path against the sensor's operate and release thresholds; the largest field at the magnet face is rarely the acceptance criterion.[6]
Write a field requirement that can be checked
“At least 3,000 gauss” leaves the measurement point and method undefined. Here is a completed teaching example for a loose axially magnetized disc. All limits, tolerances and readings below are invented to demonstrate the record; they are not a product specification or a test report.
- Part and datum
- Teaching disc D10×3, drawing DEMO-01 rev A; centre of the north pole face is the datum; +z points out of that face.
- Measurement
- Bz with the probe's positive sensitive axis along +z. Active-element centre at z = 1.00 ± 0.05 mm and within 0.05 mm of the disc axis.
- Conditions
- 20 ± 2°C, loose part in a nonmagnetic fixture, no steel backing or adjacent magnet. Zero by the instrument's procedure; record instrument/probe ID and current calibration status with the actual test.
- Assumed acceptance rule
- Application owner specifies +2,700 to +2,900 G. In this example, accept only if every reading plus its stated ±30 G expanded uncertainty interval stays within those limits. The assumed uncertainty (k = 2) includes instrument, fixture and temperature effects.
- Three separate placements
- Invented readings: +2,780, +2,760 and +2,790 G. Spread: 30 G. The combined uncertainty intervals extend from +2,730 to +2,820 G, inside the stated limits.
Decision under this teaching rule: accept this sample for this Bz check. A 2,715 G reading would overlap the lower limit once ±30 G is included, so it would need review under the same rule. The theoretical 2,786 G from the earlier model is a prediction, not the origin of the acceptance limits. An actual uncertainty allowance must be established for the real measurement setup; repeatability alone does not establish it.
Use the blank checklist for your own application. If you only have a gauss number or a sensor that fails to switch, send that information first. We can help identify the missing position, direction and assembly details for the component enquiry.
Required measurement: B component / field map / magnetic moment Part drawing and magnetic orientation: Point or scan path relative to a named datum: Sensor active-element distance and sensitive direction: Fixture, surrounding steel and installed / loose condition: Temperature, instrument range and calibration: Acceptance limits and measurement uncertainty / decision rule:
When a surface reading is the wrong test
| Quantity | SI unit | What it describes |
|---|---|---|
| Flux density B | T | The field at a specified point or a defined material state |
| Field strength H | A/m | Magnetizing field; in air B ≈ μ₀H, but this relation alone does not describe a magnet's interior |
| Magnetization M | A/m | Magnetic dipole moment per unit volume |
| Magnetic polarization J = μ₀M | T | The material contribution in B = μ₀H + J |
| Magnetic moment m | A·m² | The integrated magnetic moment of the sample |
| Pull force | N | A mechanical result for a defined target, gap and loading direction |
Choose the quantity before the test
Flux density B
- SI unit
- T
- What it describes
- The field at a specified point or a defined material state
Field strength H
- SI unit
- A/m
- What it describes
- Magnetizing field; in air B ≈ μ₀H, but this relation alone does not describe a magnet's interior
Magnetization M
- SI unit
- A/m
- What it describes
- Magnetic dipole moment per unit volume
Magnetic polarization J = μ₀M
- SI unit
- T
- What it describes
- The material contribution in B = μ₀H + J
Magnetic moment m
- SI unit
- A·m²
- What it describes
- The integrated magnetic moment of the sample
Pull force
- SI unit
- N
- What it describes
- A mechanical result for a defined target, gap and loading direction
For uniform magnetization, m = MV; for a nonuniform sample, integrate M over its volume. For example, an assumed M = 1.0 × 106 A/m in 1.0 cm³ (10−6 m³) gives m = 1.0 A·m². This uses a specified magnetization, not a surface-gauss reading. 1 emu of magnetic moment = 10−3 A·m²; volume- or mass-normalized reports use different units.[1] [2]
To compare whole-part magnetic moment: a suitable coil and fluxmeter arrangement can integrate the sample's response during a controlled movement or rotation. Coil calibration, sample size and the movement procedure matter. A Hall probe at one point does not directly measure total moment.[7]
To confirm material remanence or coercivity: use an appropriate hysteresis measurement and sample definition. Surface flux alone cannot identify a grade because geometry, magnetization state and position all affect it. Open-circuit measurements also need attention to the specimen's demagnetizing field; see how to read a hysteresis loop.
Saturation magnetization Ms describes the material's high-field magnetization limit under stated conditions. It is neither a surface-gauss target nor the remanent value after reducing the field. A request for “saturation in tesla” must establish whether it means magnetic polarization μ₀Ms or an applied-field axis.
To confirm holding force: use a force test with the actual target and defined separation and load direction. Two magnets with the same centre gauss reading can have different pole areas and force distributions. The pull-force guide explains why a local field reading cannot be converted directly to kilograms of holding capacity.[8]
Technical sources
Read each source with its stated material, test conditions and publication scope.
- NIST: Magnetic units conversion chart
- NPL: Measurement of magnetic dipole moment
- K&J Magnetics: Guide to measuring magnetic strength
- Arnold: Magnetic properties and measuring techniques
- Lake Shore: Hall probe selection guide
- Texas Instruments: Magnetic sensing proximity tool
- Lake Shore: Permanent magnet measurements with fluxmeter and Helmholtz coil
- Adams Magnetic Products: What gauss measures