Magnet trading · Nike Industrial Trading[email protected]WhatsApp +852 4607 0157

Magnet materials and specifications

Neodymium magnet field strength and gauss measurement

1 tesla equals 10,000 gauss. In the calculated 10×3 mm cylinder example, field falls from about 3,344 G at the face to 253 G at 10 mm. Use a defined measurement point and method when comparing parts.

Nike Industrial Trading Published 5 November 2026

Equivalent flux-density values: 0.1 tesla, 100 millitesla and 1000 gauss
The same flux density in three units. A measurement still needs a defined position and direction.

How many tesla is a neodymium magnet?

The answer depends on where you measure. In the 10×3 mm cylinder example below, calculated field falls from about 0.334 T at the pole centre to 0.025 T at 10 mm away. The magnet and material have not changed; the measurement position has.

1 tesla = 10,000 gauss; 1 mT = 10 gauss. A reading of 250 mT is 2,500 G. A Hall probe measures flux density at its active element in a defined direction. That local reading differs from material remanence Br and from a pull-force rating.[1]

Why distance changes a gauss reading

Consider an ideal axially magnetized cylinder, 10 mm in diameter and 3 mm thick, with Br = 1.30 T. The following estimate uses uniform magnetization and a recoil relative permeability approximated as one, with no nearby steel or other magnets. It is an educational calculation, not a measurement or a promised product value.

Calculated axial field above the centre of the pole face
Distance zBz (T), approx.Gauss, approx.
0 mm0.334 T3,344 G
1 mm0.279 T2,786 G
3 mm0.165 T1,649 G
5 mm0.092 T916 G
10 mm0.025 T253 G
The distance z ends at the probe’s active element, not its casing. The calculated centreline curve uses the same assumptions as the worked table.

The estimate is Bz = (Br/2) × [(z + t)/√(R² + (z + t)²) − z/√(R² + z²)], where R = 5 mm and t = 3 mm. Use one length unit consistently. The reduction comes from geometry and distance, not a change in grade. The calculation is for the centreline, so it cannot predict the field at a corner or the transverse component.

A probe housing touching the magnet does not put its active sensor at z = 0. Its internal setback adds separation. Probe size also matters: in a steep gradient, a finite sensing area averages a region instead of sampling an infinitesimal point. K&J's measurement example and Arnold's measurement guide explain both problems.[3] [4]

A repeatable Hall-probe measurement

  1. Choose the quantity and range. Specify Bz, another component, or a three-axis vector magnitude. Confirm the probe orientation, measurement range and calibration.
  2. Locate the active element. Use the probe manufacturer's mechanical drawing. Reference the sensing area to a magnet datum, not just the outer probe tip.
  3. Fix the geometry. Use a nonmagnetic fixture with a stop for distance and lateral position. Keep other magnets, steel tools and supports out of the measurement region.
  4. Control zero and temperature. Follow the instrument's zeroing procedure and record the measurement temperature. Do not assume an arbitrary point on the bench is field-free.
  5. Check repeatability. Remove and reseat the part several times. Record the spread before setting an acceptance window tighter than the fixture can reproduce.

A one-axis probe rotated by an angle θ from a locally uniform field measures approximately B cos θ. That relationship does not correct an unknown three-dimensional field or a position error. Probe documentation identifies the sensitive axis and active area; use those details in the fixture drawing.[5]

For a ring with a multipole pattern, one centre reading can miss a reversed or weak pole. Define angular positions, radius, height and rotation direction for a field scan. For a Hall-switch application, check field along the full motion path against the sensor's operate and release thresholds; the largest field at the magnet face is rarely the acceptance criterion.[6]

Write a field requirement that can be checked

“At least 3,000 gauss” leaves the measurement point and method undefined. Here is a completed teaching example for a loose axially magnetized disc. All limits, tolerances and readings below are invented to demonstrate the record; they are not a product specification or a test report.

Part and datum
Teaching disc D10×3, drawing DEMO-01 rev A; centre of the north pole face is the datum; +z points out of that face.
Measurement
Bz with the probe's positive sensitive axis along +z. Active-element centre at z = 1.00 ± 0.05 mm and within 0.05 mm of the disc axis.
Conditions
20 ± 2°C, loose part in a nonmagnetic fixture, no steel backing or adjacent magnet. Zero by the instrument's procedure; record instrument/probe ID and current calibration status with the actual test.
Assumed acceptance rule
Application owner specifies +2,700 to +2,900 G. In this example, accept only if every reading plus its stated ±30 G expanded uncertainty interval stays within those limits. The assumed uncertainty (k = 2) includes instrument, fixture and temperature effects.
Three separate placements
Invented readings: +2,780, +2,760 and +2,790 G. Spread: 30 G. The combined uncertainty intervals extend from +2,730 to +2,820 G, inside the stated limits.

Decision under this teaching rule: accept this sample for this Bz check. A 2,715 G reading would overlap the lower limit once ±30 G is included, so it would need review under the same rule. The theoretical 2,786 G from the earlier model is a prediction, not the origin of the acceptance limits. An actual uncertainty allowance must be established for the real measurement setup; repeatability alone does not establish it.

Use the blank checklist for your own application. If you only have a gauss number or a sensor that fails to switch, send that information first. We can help identify the missing position, direction and assembly details for the component enquiry.

Required measurement: B component / field map / magnetic moment
Part drawing and magnetic orientation:
Point or scan path relative to a named datum:
Sensor active-element distance and sensitive direction:
Fixture, surrounding steel and installed / loose condition:
Temperature, instrument range and calibration:
Acceptance limits and measurement uncertainty / decision rule:

When a surface reading is the wrong test

Choose the quantity before the test
QuantitySI unitWhat it describes
Flux density BTThe field at a specified point or a defined material state
Field strength HA/mMagnetizing field; in air B ≈ μ₀H, but this relation alone does not describe a magnet's interior
Magnetization MA/mMagnetic dipole moment per unit volume
Magnetic polarization J = μ₀MTThe material contribution in B = μ₀H + J
Magnetic moment mA·m²The integrated magnetic moment of the sample
Pull forceNA mechanical result for a defined target, gap and loading direction

Choose the quantity before the test

Flux density B

SI unit
T
What it describes
The field at a specified point or a defined material state

Field strength H

SI unit
A/m
What it describes
Magnetizing field; in air B ≈ μ₀H, but this relation alone does not describe a magnet's interior

Magnetization M

SI unit
A/m
What it describes
Magnetic dipole moment per unit volume

Magnetic polarization J = μ₀M

SI unit
T
What it describes
The material contribution in B = μ₀H + J

Magnetic moment m

SI unit
A·m²
What it describes
The integrated magnetic moment of the sample

Pull force

SI unit
N
What it describes
A mechanical result for a defined target, gap and loading direction

For uniform magnetization, m = MV; for a nonuniform sample, integrate M over its volume. For example, an assumed M = 1.0 × 106 A/m in 1.0 cm³ (10−6 m³) gives m = 1.0 A·m². This uses a specified magnetization, not a surface-gauss reading. 1 emu of magnetic moment = 10−3 A·m²; volume- or mass-normalized reports use different units.[1] [2]

To compare whole-part magnetic moment: a suitable coil and fluxmeter arrangement can integrate the sample's response during a controlled movement or rotation. Coil calibration, sample size and the movement procedure matter. A Hall probe at one point does not directly measure total moment.[7]

To confirm material remanence or coercivity: use an appropriate hysteresis measurement and sample definition. Surface flux alone cannot identify a grade because geometry, magnetization state and position all affect it. Open-circuit measurements also need attention to the specimen's demagnetizing field; see how to read a hysteresis loop.

Saturation magnetization Ms describes the material's high-field magnetization limit under stated conditions. It is neither a surface-gauss target nor the remanent value after reducing the field. A request for “saturation in tesla” must establish whether it means magnetic polarization μ₀Ms or an applied-field axis.

To confirm holding force: use a force test with the actual target and defined separation and load direction. Two magnets with the same centre gauss reading can have different pole areas and force distributions. The pull-force guide explains why a local field reading cannot be converted directly to kilograms of holding capacity.[8]

Technical sources

Read each source with its stated material, test conditions and publication scope.

  1. NIST: Magnetic units conversion chart
  2. NPL: Measurement of magnetic dipole moment
  3. K&J Magnetics: Guide to measuring magnetic strength
  4. Arnold: Magnetic properties and measuring techniques
  5. Lake Shore: Hall probe selection guide
  6. Texas Instruments: Magnetic sensing proximity tool
  7. Lake Shore: Permanent magnet measurements with fluxmeter and Helmholtz coil
  8. Adams Magnetic Products: What gauss measures

Have a gauss requirement to clarify?

Send the drawing or existing gauss requirement and explain what the magnet must operate or detect. Add your measurement setup if one exists.

Discuss a field requirement