Magnet trading · Nike Industrial Trading[email protected]WhatsApp +852 4607 0157

Magnet materials and specifications

NdFeB saturation magnetization and remanence

Saturation magnetization describes the high-field material response. In SI, Js = μ₀Ms expresses it in tesla. In one published experiment, the same sintered specimen measured 1.47 T at saturation and 1.33 T at remanence.

Nike Industrial Trading Published 6 November 2026

De Groot sintered specimen 1:0 measured saturation polarization 1.47 T and remanent polarization 1.33 T
Reported results for the same 1:0 sintered specimen in de Groot et al., Table I.

Which quantity does “saturation” refer to?

Saturation magnetization Ms describes the high-field magnetization of a given material at a stated temperature. In SI, magnetization M is magnetic moment per volume, in A/m. Saturation polarization Js = μ0Ms gives the same material contribution in tesla. Remanence Br is the B value at H = 0 on the descending branch after saturation. [1] [2] [3]

Three labels commonly confused in magnetic data
QuantitySI unitWhere to read it
MsA/mHigh-field limit of M
JsTHigh-field limit of J = μ0M
BrTAt zero internal H after saturation

Since B = μ0H + J, total B keeps increasing as H rises even when J is nearly flat. Some material publications use tesla for “saturation magnetization” as shorthand for μ0Ms. If a chart gives a tesla value, check whether it plots J, total B, or the applied field expressed as μ0H. [1] [3]

Conceptual positive-field branch. Polarization approaches a plateau while total B includes μ₀H. They meet at zero internal H after saturation.

What the often-quoted 1.6 T applies to

About 1.6 T is a room-temperature saturation polarization reference for the Nd2Fe14B phase. It corresponds to Ms ≈ 1.27 MA/m using μ0 ≈ 4π × 10−7 H/m. It should not be entered as the Br, pole-face field or magnetizing fixture setting of an arbitrary commercial part. A published number must identify whether it describes a phase, a single crystal or a manufactured specimen. [4] [5]

For a finished-material example, de Groot and colleagues report measured Js = 1.47 T and Jr = 1.33 T for the undoped 1:0 specimen in Table I of their sintered-magnet study. They used a vibrating sample magnetometer with a maximum field capability of 7.2 MA/m. The ratio 1.33/1.47 is about 0.905 for this sample. The reported saturation and remanence are two readings of one material, not two possible readings of the same point on the curve. [4]

Composition changes intrinsic saturation, while phase fraction and dilution affect the manufactured material. For instance, a single-crystal study of cerium substitution explicitly compares the saturation magnetization of substituted and undoped compositions at 300 K. Grain orientation and reversal after removing the field affect the remanent result. This is why a phase value and an N-grade datasheet cannot be compared as if they described two finished samples. [4] [6]

How to verify a reported saturation value

  1. Identify the ordinate and normalization. A magnetometer may report moment m in A·m², mass magnetization in A·m²/kg or volume magnetization in A/m. Divide by the corresponding specimen volume or use its density to convert mass magnetization. A per-formula-unit value needs the formula-unit volume to convert to A/m. [1] [6]
  2. Check direction, temperature and usable field. An easy-axis sweep can approach saturation at a lower field than a hard-axis sweep. Verify that the instrument reached a field sufficient for the specimen and the reported method. A pre-magnetized sample's demagnetization curve is useful for Br and coercivity but does not, by itself, demonstrate a high-field Ms plateau in that setup. [7] [8]
  3. Check the field basis and corrections. For open-circuit data, the applied field and internal field differ because of the specimen's self-demagnetizing field. Record the sample shape, correction, background and any high-field fit used to estimate Ms. Geometry can also affect the instrument's reported moment through the pickup-coil response. If the available field was insufficient, report the result at the measured field or identify the estimate and its method. [9] [10] [11]

Unit exercise: If a sample's mass saturation magnetization is 150 A·m²/kg and its measured density is 7,400 kg/m³, then Ms is 1.11 MA/m and Js is approximately 1.39 T. These are illustrative inputs. Keep the density and the magnetic value on the same sample basis, particularly for porous material or a powder and binder composite. [1]

How this applies to a component specification

Use Ms or Js when comparing intrinsic material measurements on the same basis. Use Br and the grade data when the design input is zero-field remanence. If the problem is weak output after magnetizing a part, compare stable remanence or a defined part flux metric as pulse amplitude is increased on equivalent specimens. Confirm the fixture field direction and penetration, then compare with the agreed production criterion. The reported Js is not the amplitude to set on the magnetizer. [8]

You can start with the value and units you have, a photo of the report, or a description of the weak output. Leave unknown entries below blank or mark them “unknown”. First establish what was measured and what the component needs to do, then identify the material or test information still needed.

Material form, grade and composition if known:
Quantity shown, units and normalization basis:
Sample geometry, direction and temperature:
Maximum applied field and internal-field correction:
Observed high-field plateau or fitting method:
Finished part flux or remanence criterion, if relevant:

Technical sources

Read each source with its stated material, test conditions and publication scope.

  1. NIST: Units for magnetic properties
  2. Arnold: Measuring magnetic properties
  3. Coey: Perspective and prospects for rare-earth permanent magnets
  4. de Groot et al.: Sintered NdFeB and DyGa additions
  5. NIMS and JST: Intrinsic polarization comparison with Nd2Fe14B
  6. Susner et al.: Ce-substituted Nd2Fe14B single crystals
  7. Lake Shore: Characterizing permanent magnets with an 8600 VSM
  8. IEC TR 62517:2009: Magnetizing behaviour
  9. Lake Shore: Permanent magnet measurements with a VSM
  10. IEC 60404-18:2025: Open-circuit measurements
  11. Quantum Design: Reported moment and sample shape

Checking a reported saturation value?

Share the plot and units if available, or describe the part and its output problem. We can first clarify whether the question concerns a material value or the finished part's flux.

Discuss magnetic measurement data