Design the mold around the functional drawing
A mold for an injection-molded NdFeB magnet must fill the part with the selected compound and support the intended magnetic result. Start with the surfaces that locate the part, its fit and the required magnetization. Mark where a gate vestige, parting line or ejector mark is acceptable. A sensor ring also needs a mechanical angular datum and a defined measurement track when its signal must match shaft position.[1] [2] [3]
This guide applies to a thermoplastic-bonded compound with retained binder. Use the part's function to select the inputs below. The later ring example shows how tooling can affect a position signal. The injection molding process guide covers the manufacturing sequence. A compression-bonded part requires a different die and process review.
| Part or application | Drawing and tool inputs | Magnetic check |
|---|---|---|
| Simple block or disc | Identify the seating face, fitting dimensions and allowed gate and ejector zones. For a disc, distinguish axial thickness from diameter. Keep marks clear of mating or bonding faces where they would affect the joint. | Show the magnetization direction relative to the part. Define the field or flux check and its fixture. An angular datum is needed only when the function depends on rotation about that axis. |
| Part molded around an insert | Provide the insert drawing, locating features and retention requirement. Identify surfaces that remain exposed, then review filling, shrinkage and release around the insert. | Relate the required polarity to the insert or assembly datum. Review access for magnetizing and measurement with the insert in place. |
| Encoder or position-sensor ring | Define the bore or hub location, allowed runout, mechanical zero and surfaces near the sensor. Keep gate and ejector locations tied to those features. | Specify pole count, polarity, angular phase when required, and the field component measured at a stated track and stand-off. Relate the pole map to the mechanical datum. |
Choose the design inputs that apply to the part
Simple block or disc
- Drawing and tool inputs
- Identify the seating face, fitting dimensions and allowed gate and ejector zones. For a disc, distinguish axial thickness from diameter. Keep marks clear of mating or bonding faces where they would affect the joint.
- Magnetic check
- Show the magnetization direction relative to the part. Define the field or flux check and its fixture. An angular datum is needed only when the function depends on rotation about that axis.
Part molded around an insert
- Drawing and tool inputs
- Provide the insert drawing, locating features and retention requirement. Identify surfaces that remain exposed, then review filling, shrinkage and release around the insert.
- Magnetic check
- Relate the required polarity to the insert or assembly datum. Review access for magnetizing and measurement with the insert in place.
Encoder or position-sensor ring
- Drawing and tool inputs
- Define the bore or hub location, allowed runout, mechanical zero and surfaces near the sensor. Keep gate and ejector locations tied to those features.
- Magnetic check
- Specify pole count, polarity, angular phase when required, and the field component measured at a stated track and stand-off. Relate the pole map to the mechanical datum.
These are drawing inputs to discuss with the tool designer. The selected compound and geometry determine the actual tooling allowances. Injection molding can accommodate simple and complex shapes, while shrinkage varies with shape and thickness.[4] [8] [10]
Choose gate and vent candidates against the critical regions
Draw the expected flow paths, including paths around any core or insert, and identify where fronts meet. Compare candidate gate positions against the part's critical regions. These may include a mating face, precision bore, exposed surface or stressed mounting feature. A sensor ring also needs the flow pattern reviewed against its measurement track. One gate can simplify trimming but may leave a longer flow path. Multiple gates can shorten that path while creating more potential meeting lines. Place vents where the selected fill pattern displaces air, and validate the actual result with the specific compound and trial parts.[4] [5]
Kurth and colleagues compared gate arrangements for a 24-pole, pole-oriented ring made from PA12 and strontium ferrite. In their trial, an injection point at a pole center tended to shorten that pole, and a weld line at a pole center tended to broaden it. Their favorable configurations included a film gate or a specific twelve-point layout. The experiment used ferrite. It identifies a mechanism worth checking in NdFeB rings, while the gate count, geometry and magnetic effect need verification on the NdFeB compound and tool.[1]
Separate cavity alignment from the final magnetizer
| Material route | Mold review | Final magnetic review |
|---|---|---|
| Isotropic NdFeB compound | Establish fill, fit and a reliable datum for the later fixture. A preferred powder orientation is unnecessary. | Check fixture access, final polarity and the field or flux at the specified measurement location. For a multipole part, include pole transitions and any required angular indexing. |
| Anisotropic NdFeB compound | Review the orienting field direction and strength through the volume while the material is mobile. Cavity geometry, tool materials and cooling can affect the result. | Confirm the final magnetization step and field or flux requirement. Check whether the tool produces adequate orientation near the ends and thin sections. A sensor ring may need a scan around the full measurement track. |
What the molding tool and magnetizing fixture each need
Isotropic NdFeB compound
- Mold review
- Establish fill, fit and a reliable datum for the later fixture. A preferred powder orientation is unnecessary.
- Final magnetic review
- Check fixture access, final polarity and the field or flux at the specified measurement location. For a multipole part, include pole transitions and any required angular indexing.
Anisotropic NdFeB compound
- Mold review
- Review the orienting field direction and strength through the volume while the material is mobile. Cavity geometry, tool materials and cooling can affect the result.
- Final magnetic review
- Confirm the final magnetization step and field or flux requirement. Check whether the tool produces adequate orientation near the ends and thin sections. A sensor ring may need a scan around the full measurement track.
A published NdFeB-specific example used an HDDR-derived compound and a Halbach powder-aligning fixture. Zhu and colleagues compared calculated fields with measurements and found that the cavity end field could differ from the mid-plane field. Their geometry and magnet arrangement belong to the specific experiment. The transferable tool-review question is whether adequate field direction and magnitude extend across the functional volume, rather than only at one center-plane point.[2] [3] [6]
Set the locating features and fit before tool allowances
- Locating and mating surfaces. State the features that position the part in its assembly. For a block or disc, identify the seating face and fitting dimensions. For a ring, specify the locating bore or hub, permitted runout and diameter condition after any finish.
- Insert and part release. Fix the insert orientation and retention requirement. Review the parting line, draft and ejection locations against those features before freezing the cavity.
- Fit after conditioning. A compound sheet may give shrinkage for a test specimen. Use the chosen compound, local geometry and trial measurements to set cavity compensation. Compare cavities separately where more than one is used.
As a dimensional illustration, if a uniform shrinkage estimate is 0.4% relative to cavity diameter, a free 30.000 mm molded diameter implies an initial calculation of 30.000 ÷ 0.996 ≈ 30.120 mm for the cavity. This arithmetic assumes uniform, unconstrained shrinkage. Newland’s PA12 compound table reports a specimen shrinkage value, while Arnold notes that thickness and shape influence finished variation. For a constrained hub or directional shrinkage, use the compound data and trial results to set the allowance. Bunting’s multicavity process description illustrates why the number of cavities is a separate tool choice.[7] [8] [9] [10]
Mechanical pole angles in an eight-pole ring
For a teaching example, eight equal poles on a ring give a mechanical pole pitch of 360° ÷ 8 = 45°. If the drawing places a pole center at a keyed zero, adjacent transitions lie nominally at ±22.5°. At a 15 mm scan radius, a 1° mechanical displacement represents about 0.262 mm of arc. That conversion helps relate an angular error to a sensor location. It does not set a permissible error.
State which field component is scanned, the radius, axial height and stand-off, the viewing direction and positive rotation. For a radial scan, define how a signed field transition is identified. Measure sample phase relative to the mechanical key and report the resulting transition angles and peak values. If the whole ring reads weakly, check fixture distance and magnetization before changing a gate. If a distortion repeats at the same cavity and aligns with a gate or weld feature, compare the flow and scan records before modifying tooling.[1] [5]
Information to send for a tool review
Start with the current drawing or a sketch and identify the fit, holding or sensing requirement that drives the part. Leave unknown details open. For a simple block or disc, describe the seating face and intended magnetization. Add a scan track and angular phase only when the application uses them.
Part drawing revision and insert drawing, if applicable: Compound, binder and orientation route, if known: Critical surfaces, fit and allowed gate/ejector zones: Magnetization direction or pole pattern relative to part features: Field or flux requirement and measurement fixture, if specified: For indexed sensor parts: angular datum, rotation convention and scan track: Dimensional and magnetic evidence requested at first article: Sample quantity, cavity traceability and production volume:
Technical sources
Read each source with its stated material, test conditions and publication scope.
- Kurth et al.: injection points and pole length in bonded rings
- Zhu et al.: aligning fixture for anisotropic bonded NdFeB rings
- Polymer-bonded magnets: molding influences
- Moldflow: selecting injection locations
- Moldflow: troubleshooting weld and meld lines
- Plastic-bonded injection-molded NdFeB magnets
- PA12 and PPS NdFeB injection granules
- Injection molded magnet capabilities
- Plastic-bonded NdFeB product information
- Injection molded magnets for magnetic applications